This guide separates the robot workstation from the OpenPI Policy/training server. They have different Python and CUDA requirements and should not share one environment.
| Component | Tested platform | Python |
|---|---|---|
| Collection GUI, data tools, RTC client | Ubuntu 22.04, x86_64 | 3.10.20 |
| Dashboard and OpenPI Policy server | Ubuntu 22.04, NVIDIA GPU | 3.11.15 |
| RoboTwin/cuRobo evaluation | Ubuntu 22.04, CUDA 12.1 | 3.10/3.11 |
The commands below assume a Conda-compatible installation such as Miniconda, Mambaforge, or Anaconda. Windows and macOS are not supported for Piper CAN control.
Install the robot-workstation tools on Ubuntu:
sudo apt-get update
sudo apt-get install -y \
build-essential \
can-utils \
ffmpeg \
git \
iproute2 \
libgl1 \
libglib2.0-0 \
python3-tk \
v4l-utils
The Linux kernel must expose the USB-CAN adapters through SocketCAN. The
official Piper USB-CAN adapter should normally appear with the gs_usb driver.
git clone https://github.com/SUNNYsyy2005/bimanual-vla.git
cd bimanual-vla
Create the environment:
conda create -n dual_arm python=3.10.20 -y
conda activate dual_arm
python -m pip install --upgrade pip setuptools wheel
python -m pip install -r requirements.txt
requirements.txt covers:
The public OpenPI client is pinned to 0.1.2; its WebSocket API is compatible
with the source-installed 0.1.0 client used on the verified workstation.
NumPy is intentionally constrained to 1.26.4 because both client versions
declare numpy<2.
Verify the Python environment:
python - <<'PY'
import cv2
import flask
import numpy
import pandas
import pyarrow
import scipy
from PIL import Image
from openpi_client import websocket_client_policy
from piper_sdk import C_PiperInterface_V2
print("Python dependencies: OK")
PY
python -m pip check
bin/bimanual-vla --help
Check the non-GUI command entry points without connecting hardware:
for command in \
collect-output teleop-bimanual teleop-single home-single \
data-check data-export data-upload data-validate data-view rtc-client
do
bin/bimanual-vla "$command" --help >/dev/null
done
echo "Non-GUI CLI entry points: OK"
collect-gui starts the Tk application directly, so it is intentionally not
included in the --help loop. Validate it with bash start_gui.sh in a desktop
session.
Connect and power the Piper arms before activating their CAN interfaces. Identify the adapters:
lsusb -t
ip -br link show type can
Activate a single arm at 1 Mbit/s:
sudo ip link set can0 down 2>/dev/null || true
sudo ip link set can0 type can bitrate 1000000 restart-ms 100
sudo ip link set can0 up
ip -s -details link show can0
timeout 2 candump -L can0
For the current bimanual GUI, repeat the commands for can1. Verify the
physical left/right mapping before enabling or commanding either arm; interface
numbers can change when USB adapters are reconnected.
The repository can also use the Piper SDK activation helper when that SDK checkout is available:
export BIMANUAL_VLA_CAN_ACTIVATE_SCRIPT="/path/to/piper_sdk/piper_sdk/can_activate.sh"
bash start_gui.sh
List the V4L2 devices and formats:
v4l2-ctl --list-devices
for device in /dev/video*; do
printf '%s\n' "$device"
v4l2-ctl -d "$device" --get-fmt-video 2>/dev/null || true
done
The current rig uses:
cam_high;cam_left_wrist;cam_right_wrist.The software prefers stable /dev/v4l/by-path selectors. Confirm all three GUI
previews after reconnecting cameras instead of relying on old /dev/videoN
numbers. Depth and grayscale nodes are not valid RGB inputs.
conda activate dual_arm
bash start_gui.sh
The launcher uses the active environment first. If that Python lacks Tk, it
checks the conventional Conda dual_arm environment under the current home
directory. You can select another interpreter with
BIMANUAL_VLA_PYTHON; that interpreter must include Tk support (tk in Conda
or python3-tk for the matching Ubuntu system Python).
The GUI can be opened without connected hardware, but collection requires fresh
CAN feedback and valid camera frames. See
docs/collection/GUI_OPERATION_GUIDE.md for the operating workflow.
The validation and conversion commands do not require a connected robot:
bin/bimanual-vla data-validate --help
bin/bimanual-vla data-export --help
bin/bimanual-vla data-check --help
bin/bimanual-vla data-upload --help
Run the automated test suite from the repository root:
python -m unittest discover -s tests -v
The Policy server is a separate environment. Do not install the root
requirements.txt over a working OpenPI/JAX environment.
The current Dashboard expects an OpenPI checkout that contains the Piper
training configs and exposes these paths in server_4090/config.json:
{
"openpi_repo": "/path/to/openpi",
"openpi_python": "/path/to/openpi-python",
"dataset_root": "/path/to/lerobot",
"assets_base_dir": "/path/to/openpi/assets",
"checkpoint_base_dir": "/path/to/openpi/checkpoints",
"base_checkpoint": "/path/to/pi05_base"
}
The verified OpenPI source revision is:
repository: https://github.com/Physical-Intelligence/openpi.git
revision: 15a9616a00943ada6c20a0f158e3adb39df2ccac
Python: 3.11
Install the base OpenPI environment using its own upstream uv workflow:
git clone https://github.com/Physical-Intelligence/openpi.git
cd openpi
git checkout 15a9616a00943ada6c20a0f158e3adb39df2ccac
curl -LsSf https://astral.sh/uv/install.sh | sh
GIT_LFS_SKIP_SMUDGE=1 uv sync
The upstream checkout alone does not provide this project’s custom Piper training configs. Install or synchronize the validated Piper/OpenPI integration used by your deployment before starting norm, training, or Policy tasks.
Download the pi0.5 base checkpoint from the bimanual-vla repository:
python -m scripts.models.download_openpi_checkpoint \
--checkpoint gs://openpi-assets/checkpoints/pi05_base \
--source auto \
--workers 16 \
--chunks-per-file 16
Create the local Dashboard config:
cp server_4090/config.example.json server_4090/config.json
Edit only the local config.json; do not commit machine-specific paths or
credentials. Start the service in the foreground for the first validation:
bash server_4090/run_server_foreground.sh
Then check:
curl -fsS http://127.0.0.1:8090/healthz
For the established 4 x RTX 4090 host and user-level systemd deployment, use:
bash deploy_4090_server.sh
This command requires a working SSH host alias and matching remote paths. It does not install CUDA or create the OpenPI environment.
H100/H200 jobs use the dedicated OpenPI environment and must run through Slurm. Before submission, verify:
hostname
pwd
resources
myquota
Do not train, run inference, or process large datasets on login-server.
Submit the preparation and training jobs with sbatch, or use the Dashboard
API described in server_4090/API_USAGE.md.
RoboTwin, SAPIEN, and cuRobo use a separate CUDA 12.1-compatible environment.
They are intentionally excluded from requirements.txt. Follow
docs/deployment/SERVER_PATHS_ENV_TRAIN_EVAL.md for the currently validated
environment and rollout commands.
ModuleNotFoundError: piper_sdkConfirm the active environment and reinstall the pinned SDK:
conda activate dual_arm
python -m pip install piper_sdk==0.6.1
No such device: can0Check that the adapter uses gs_usb, then reactivate SocketCAN:
lsusb -t
ip -br link show type can
Use v4l2-ctl --list-devices and select an RGB/YUYV/MJPEG node. Do not select
Z16 depth or GREY infrared nodes.
sudo apt-get install -y python3-tk
Recreate the Conda environment after installing Tk if the active Python still
cannot import tkinter.
Do not mix the robot workstation environment with OpenPI or cuRobo. Confirm the host-specific Python, CUDA toolkit, driver, and checkpoint format described in the deployment documentation.
server_4090/config.json machine-local when it contains private paths.--allow-execution for the first Policy check.EXECUTE authorization.